Inter-Row Spacing in the Rooftop Solar Projects

Introduction

Solar rooftop projects are built with a ploy of maximizing energy density in the available roof area. Solar rooftop panels are mostly tilted based on their geographical location to achieve their most efficient performance. These tilted panels, in turn, cast shadows on the successive panels behind them, necessitating a defined gap between them to reduce the losses that may incur due to shadow. Therefore, an optimum spacing between the panel rows needs to be decided. Let us see in detail about the row spacing and automating the row spacing for rooftop projects in this article.

Row spacing

To have a clear overview of row spacing among rooftop panels let us consider the image below,

Rooftop Solar Project

In this picture, one could visualize the effect of one panel on another about the shadow imposed. You can also see the panels are placed with a defined spacing along the rows to eliminate the effect of shadows.

Illustration

To conceptualize the row spacing let us consider the below illustration.

Row Spacing Illustration

Row-spacing calculation

It is clear from the above illustration that row spacing plays a significant role in the performance of the rooftop panels by adding or preventing shades. To find the desired row spacing for any rooftop it is obvious that there are certain panel characteristics, locations, and available areas. Optimizing of use of available roofs being the ultimate goal for any consumer could be achieved by effective row spacing.

The effective row spacing between the panels is decided by,

  • Panel Tilt (β)
  • Panel width (w)
  • Height difference (H)
  • Shadow angle and Azimuth angle(α)

The Tilt angle of a panel varies with the location of the roof and is the most significant factor in deciding the row spacing. It is the angle between the solar panel and the roof base. The shadow pattern is derived from the tilt as well as the height of the panel. The shadow angle is calculated mostly on the winter solstice when one can experience more shadows for any objects owing to the Sun’s position.

The azimuth angle is the angle through which the sun rays penetrate the panels. The tilt angle is decided in such a way that the panel is almost perpendicular to the direction of the solar radiation. This ensures the panel has an optimal generation from solar radiation.

Interpretations done

The steps involved in finding the optimum row spacing are,

Step 1: Height difference

Using the table width and tilt angle, we can find the height difference of a panel.

Height difference (H) = Panel width × Tilt (sin of tilted degrees)

Step 2: Module row spacing

With height difference and solar angle, we can find the module row spacing using,

Module row spacing = Height difference / Tan (Solar elevation angle)

Step 3: Minimum module row spacing

This is the minimum distance required to be decided between the modules to effective performance of solar panels.

Minimum module row spacing = Module Row Spacing x Cos (Azimuth Correction Angle)

One should get their sun elevation angle and azimuth correction details from this article Sun chart program. You will get access to the pattern of solar elevation angle and associated shadow and azimuth from this resource. One must consider the desired time for the calculation of shading effects on any roof in a given region.

Sun chart – Solar elevation angle

The solar elevation article is found for a particular time say 9 am to 4 pm, that is, draw a line horizontal from the 9 – 4 time slot to find the respective solar elevation angle. 27 degrees in this case. Similarly, draw a line from the same point between 9-4 to find the azimuth correction angle. 51 degrees from the x-axis in this case.

We could use the basic trigonometry functions to find the distance between the 2 rows.

For example,

If we have a panel width of 1m and a tilt of 20 degrees, we get the height difference as

  • Height difference (H) = 1 * sin 20 = 0.342m
  • Module row spacing   = 0.342/tan (27) = 0.675 m

We have seen the calculation part for the module row spacing but, in the case of the roof, we have rows as well as columns. One more parameter needs to be considered for evaluation which is the row width. The distance between one row ends to the successive row tail or end. We use the minimum row spacing between the modules to find the row width as,

Sun chart – Azimuth correction angle
  • Minimum row spacing = Module Row Spacing x cos (Azimuth Correction Angle)

= 0.675 * Cos 52 = 0.415 m

  • Row width(W)= Minimum Module Row Spacing + cos (Tilt Angle) x Module Width

= 0.415 + (0.939) = 1.354 m

By these steps, one can fairly estimate the required row spacing data for rooftop projects.

Auto row-spacing in ARKA 360.

By following the above methods, we were able to find the row spacing for any south-facing roof projects. In ARKA 360, we can find the auto row-spacing values for any rooftop projects. On entering the desired panel make, mount height, and tilt, the design studio automatically estimates the required row spacing.

Further, there are also various solar roof spacing calculators available on the website for reference.

Row-spacing in ARKA 360

Conclusion

Row-spacing in solar rooftop projects is the most integral part of designing. Manually estimating these values consumes our valuable time. Therefore, one could design their rooftop solar projects efficiently and accurately using automated software like ARKA 360 for auto-row spacing and other salient design features. Careful consideration should be given to the below-listed factors for efficient row spacing,

  • Tilt angle and location of the mounted panel
  • Mount height and width of the solar panel
  • Azimuth angle and direction of the panel.